GENERAL
Channels
16 time-slots up to 64 frequencies
Multiplexed mode: 128
Simultaneous mode: 32
Mix mode: 512
Techniques
ECT (Eddy Current), ECA (Array), RFT (Remote Field).
EMITTERS
Voltage
0 - 24Vpp, 1V step.
Modes
Multiplexed and Simultaneous Injection
Frequency Range
10Hz to 5MHz.
RECEIVER
Gain range
0 to 40dB, 1 dB steps (Analog gain)
Algorithms
Hardware Null
Reference coil simulation
DIGITAL FUNCTIONS
A/D sampling rate
40 MSPS, 14 bits (internal processing @16 bits)
Acquisition rate
Up to 50000 acq/second
Synchronism
Internal Clock, External Digital Input, Encoder
Frequency Filters
Digital programmable FIR type,
Real Time Defect Recognition
Threshold detection
Tube-Air detection
OTHERS
ET connector
Lemo ECG.3B.318.CLN
Digital I/O
4 inputs, 4 output Isolated (TTL/ Differential)
Analog I/O
2 inputs Isolated, 2 Output Isolated. ±10V 20KHz Bandwidth
Encoder
6 encoders Isolated. TTL / Differential.
Incremental or Pulse Type.
Ethernet port
100/1000 BaseT
Dimensions
183 x 115 x 64 mm (DxWxH).
Power
100-240 Vac, 50-60Hz (20W).
ETbox2iR: 24 Vdc, 1 A max